Trenchless cable laying is a method for installing underground power cables and other utilities without the need for extensive open-cut excavation. Instead of digging a long trench, this technology uses specialized drilling and pulling equipment to create a bore underground, through which the cable or conduit is then pulled.

This method has become popular because it offers significant advantages, including:

  • Minimal Surface Disruption: It avoids major damage to roads, landscapes, and existing infrastructure.

  • Faster Installation: The process is often quicker, especially for crossing obstacles.

  • Reduced Cost: It lowers expenses associated with reinstatement, traffic management, and environmental restoration.

There are several methods of trenchless cable laying, each suited for different site conditions and project requirements. The two most common methods are:

  • Horizontal Directional Drilling (HDD): This is the most widely used method. An HDD rig creates a pilot bore along a pre-determined path. The bore is then enlarged, and the cable or conduit is pulled through from an exit pit to the entry pit. This method is ideal for crossing rivers, roads, and other busy or sensitive areas.

  • Mole Ploughing: This method is a more direct approach for laying cables in open ground, such as fields or rural areas. A powerful tractor or winch pulls a plough with a vibrating blade through the ground. The blade creates a narrow slit, and the cable is simultaneously fed into the ground directly behind the blade. This method is exceptionally fast and cost-effective for long, straight runs.

The initial equipment cost for trenchless technology can be higher, but the overall project cost is often lower than traditional trenching, especially in urban or environmentally sensitive areas. This is because trenchless laying dramatically reduces expenses related to:

  • Restoration: There is minimal need to repair roads, sidewalks, or landscaping.

  • Traffic Management: By avoiding open trenches, traffic flow is not significantly disrupted, saving time and money.

  • Environmental Remediation: Trenchless methods reduce soil disturbance and erosion, making them a more eco-friendly choice.

Trenchless cable laying is an excellent solution for a wide range of projects where traditional excavation would be difficult, disruptive, or costly. These projects include:

  • Urban Areas: Installing cables under city streets, busy intersections, and existing buildings.

  • Environmentally Sensitive Locations: Crossing waterways, wetlands, nature reserves, or protected habitats without damaging the ecosystem.

  • Infrastructure Crossings: Laying cables under railway lines, airport runways, or major highways.

  • Rough or Remote Terrain: Projects in rocky or uneven landscapes where traditional excavation is challenging.

Selecting the right machine depends on the project's specific requirements. Key technical specifications to consider include:

  • Thrust and Pullback Force: Measured in kilonewtons (kN) or tons, this determines the machine's power to push the drill string forward and pull the pipe/cable back through the bore. Higher force is needed for longer distances and harder ground conditions.

  • Maximum Drilling Distance and Diameter: This indicates the machine's capability to create bores of a certain length and width.

  • Engine Power: The horsepower or kilowatts (kW) of the engine, which is a direct indicator of the machine's overall performance.

  • Ground Conditions: The machine's ability to operate effectively in various soil types, from soft ground to hard rock.

The HDD process for cable installation typically involves three main stages:

  1. Pilot Bore: The machine drills a small-diameter pilot hole from a designated entry point to an exit point, following a carefully planned path to avoid obstacles.

  2. Pre-reaming: A reamer is attached to the drill string and pulled back through the pilot bore to enlarge the hole to the required diameter for the cable or conduit.

  3. Cable Pullback: The cable or conduit is attached to the reamer with a swivel, and the rig pulls it back through the enlarged bore, completing the installation with minimal surface disturbance.

Mole ploughs offer several distinct advantages, particularly for projects in open, rural environments:

  • Speed and Efficiency: They are significantly faster than traditional trenching methods, as they perform the digging and laying in a single, continuous operation.

  • Minimal Disruption: The narrow slit created by the blade causes very little surface damage, which greatly reduces the need for landscape restoration.

  • Cost-Effectiveness: This method reduces labor time and avoids the high costs associated with backfilling, soil disposal, and extensive site cleanup.

  • Simultaneous Installation: Many modern mole ploughs are designed to lay multiple ducts or cables, and even warning tapes, at the same time.

There are three primary methods for laying underground cables: Direct Laying, the Draw-in System, and the Solid System. Each method is chosen based on specific project requirements, considering factors like cost, soil conditions, and future maintenance needs.

The standard laying depth for 11kV underground cables is a critical consideration for safety and operational efficiency, though it varies significantly by region, country, and specific installation environment. For instance, in some standards, the minimum depth from the ground surface to the top of the cable is specified as 600mm for footpaths and 900mm for agricultural land, while other standards may specify a nominal depth of 0.8m. These depths are influenced by factors such as:

  • Soil Type and Conditions: The thermal properties of the soil are a key factor. Deeper burial in certain soils can lead to higher temperatures, impacting the cable's current-carrying capacity.

  • Location: Depths vary based on whether the cable is under a road, footpath, or in unmade/agricultural ground, where different levels of mechanical protection are required.

  • Local Regulations: Different national and regional authorities, such as SP Energy Networks or Northern Powergrid in the UK, have specific standards and depth requirements.

We recommend consulting local electrical codes and utility specifications to ensure compliance with the precise requirements of your project location.

Maintaining proper clearance between 11kV power cables and other utilities is essential to prevent damage, reduce electromagnetic interference, and ensure public safety. As per various standards, the minimum horizontal and vertical clearances vary, but common guidelines are as follows:

  • Horizontal Clearance: Typically, a minimum horizontal distance of 300mm to 500mm must be maintained between power cables and other utilities like telecommunication lines, gas lines, or water pipes.

  • Vertical Clearance (at crossings): When an 11kV cable crosses another utility, a vertical clearance of at least 300mm is generally required. In some cases, this distance may be greater and the cable may need to be protected by concrete or other materials for a specified length on both sides of the crossing.

It is crucial to obtain detailed plans of all existing underground services before any excavation work begins to prevent accidental damage. Our cable detection and laying equipment are designed to assist in such precision work.

The laying depth is a significant factor in determining a cable's current-carrying capacity, also known as ampacity. The cable generates heat, and the surrounding soil acts as a heat-dissipation medium.

  • Deeper Burial: When a cable is buried deeper, the heat has to travel a longer path through the soil to dissipate to the surface. This increases the thermal resistance and can lead to a higher operating temperature for the cable.

  • Reduced Ampacity: A higher operating temperature can exceed the cable's maximum temperature limit, which can degrade the insulation and shorten its lifespan. Therefore, a deeper burial depth typically requires a derating of the cable, meaning its maximum allowable current must be reduced to keep the temperature within safe limits.

  • Mitigation: To counteract this, it's essential to use backfill materials with low thermal resistivity or to increase the separation between cables to improve heat dissipation.

We provide a range of advanced stringing and laying equipment to ensure precise installation and optimal thermal management for your projects.

When 11kV cables are laid at shallower depths or in high-risk areas such as roads, footpaths, or industrial zones, robust mechanical protection is paramount. Key protective measures include:

  • Warning Tapes and Tiles: Laying warning tapes and protection tiles 75mm to 150mm above the cable provides a visual and physical warning to future excavators. These markers clearly identify the presence of a high-voltage cable below.

  • Cable Ducts: Enclosing the cable in a protective duct, often made of a strong material like uPVC, provides a high degree of mechanical protection. The duct should be completely embedded in a concrete surround for enhanced safety.

  • Bedding Material: The cable should be laid on a bed of fine-grained sand or a specially engineered thermal backfill material to ensure all-around support and improve heat transfer.

Our equipment portfolio includes a variety of cable rollers, drum jacks, and accessories that ensure careful and precise cable installation, minimizing the risk of damage during the laying process.

Professional Answer:

Safety and efficiency are our top priorities. To achieve this, we rely on a comprehensive set of high-quality overhead and underground cable laying equipment. Our range of products ensures every step of the installation is performed with precision.

Key equipment includes:

  • Cable Drum Jacks: Used to lift and support heavy cable drums, allowing for smooth unwinding of the cable.

  • Cable Pulling Winches: Provide the controlled force needed to pull the cable through the trench or duct without exceeding the maximum pulling tension.

  • Cable Rollers: These are placed at regular intervals in the trench to reduce friction during the pulling process and protect the cable sheath from damage.

  • Cable Pulling Grips and Swivels: Securely connect the pulling rope to the cable, with the swivel preventing twisting of the cable.

  • Dynamometers: These are crucial for monitoring and ensuring that the pulling tension does not exceed the manufacturer's specifications, preventing internal damage to the cable.

Professional Answer:

A proper 11kV underground cable laying procedure is crucial for the safety and longevity of the power network. At Ningbo Changshi, we follow a meticulous process that adheres to international standards.

The procedure can be broken down into these key stages:

  1. Route Planning and Trenching: A detailed site survey is conducted to identify the best route, avoiding existing utilities. The trench is then excavated to the required depth, which typically ranges from 750 mm to 1200 mm depending on the location (e.g., footpaths vs. roads).

  2. Trench Preparation: The bottom of the trench is prepared with a layer of sifted sand or fine soil (bedding) to protect the cable from sharp objects. This also ensures good thermal dissipation.

  3. Cable Laying: The 11kV cables are carefully unwound from the cable drum using specialized equipment like cable drum jacks, cable pulling winches, and cable rollers. These tools are essential to avoid kinks and exceeding the minimum bending radius of the cable, which can cause damage to the insulation.

  4. Protection and Backfilling: The laid cables are covered with another layer of sand, followed by mechanical protection such as concrete slabs or cable tiles. A bright warning tape is then placed above the protection layer to alert future excavators. The trench is then backfilled and compacted in layers to prevent subsidence.

Professional Answer:

Working with high-voltage equipment requires strict adherence to safety protocols. Our company emphasizes a culture of safety to protect personnel and the public. The most critical precautions include:

  • Utility Location: Before any excavation, a thorough survey is performed using ground-penetrating radar (GPR) or other detection tools to accurately locate and mark all existing underground services (gas, water, telecom). This is the single most important step to prevent accidents.

  • Personal Protective Equipment (PPE): All personnel involved are equipped with the appropriate PPE, including insulated gloves, safety helmets, high-visibility vests, and steel-toed boots.

  • Safe Digging Practices: We use manual digging methods when working within close proximity to known utility lines. Power tools and heavy machinery are used with extreme caution and only after the area has been cleared.

  • Proper Cable Handling: We never exceed the cable's specified bending radius or pulling tension. This prevents damage that could lead to future cable failure.

  • Emergency Preparedness: Clear emergency plans are established for every job site, including first-aid kits, fire extinguishers, and defined evacuation routes.

We hope these FAQs provide valuable insight into the professional practices and equipment involved in 11kV underground cable laying. As a leading manufacturer, Ningbo Changshi Electric Power Machinery Manufacturing Limited is committed to providing the highest quality tools and equipment to ensure safe and reliable electrical construction projects worldwide.

The standard procedure for 132 kV cable laying is a meticulously planned and executed process to ensure safety and long-term reliability. It typically involves several critical stages:

  1. Route Survey and Trenching: A detailed survey is performed to determine the optimal route, followed by excavation to create a trench of the correct dimensions.

  2. Cable Drum Handling: Cable drums are transported and mounted on specialized cable drum jacks or trailers, ensuring safe and controlled unreeling.

  3. Cable Pulling: A cable winch and a series of cable rollers and bellmouths are used to pull the cable into the trench or duct. The pulling tension is constantly monitored to avoid damage.

  4. Backfilling and Protection: The cable is surrounded by a bedding layer of sand, followed by concrete protective covers or tiles, and then the trench is backfilled and compacted.

  5. Jointing and Termination: Trained technicians perform specialized high voltage cable jointing and termination to connect cable sections and link them to substations or other equipment.

Successful 132 kV cable installation relies on high-quality, reliable equipment. Our comprehensive one-stop supply includes a wide array of tools designed for this exact purpose:

  • Cable Winches: For powerful and precise control during cable pulling.

  • Cable Rollers: Straight and curved rollers to guide the cable smoothly and prevent damage.

  • Cable Drum Jacks & Trailers: Hydraulic and screw-type jacks for safely lifting and positioning heavy cable drums.

  • Cable Socks & Grips: High-tensile socks and grips to securely attach the pulling line to the cable.

  • Duct Rods: Used to pull ropes or cleaning brushes through conduits before the cable is installed.

  • Cable Laying Lubricants: To reduce friction and pulling tension, protecting the cable sheath.

Safety is paramount in any 132 kV cable project. The high voltage presents significant risks that must be managed with strict adherence to safety protocols. Our key considerations and recommendations include:

  • Pre-work planning: Always obtain necessary permits and conduct thorough site surveys to identify existing underground utilities.

  • Personal Protective Equipment (PPE): All personnel must use appropriate PPE, including insulated gloves, boots, and helmets.

  • Controlled Excavation: Use hand-digging near existing cables and maintain a safe clearance distance from live services.

  • Equipment Safety: Ensure all cable pulling equipment is well-maintained and operated by trained professionals.

  • Emergency Response: Have a clear, established plan for emergency situations, including immediate reporting of any cable damage.

Efficient heat dissipation is crucial for the performance and longevity of 132 kV underground cables. The insulation and surrounding environment play a key role. Our solutions and best practices address this through:

  • Cable Design: Utilizing XLPE insulated cables with specific designs to handle thermal stress.

  • Bedding Material: Surrounding the cable with a thermal backfill material, such as specific sands, to conduct heat away from the cable.

  • Installation Depth: Laying the cables at a sufficient depth to take advantage of the ground's natural cooling properties.

  • Trefoil Formation: Arranging the single-core cables in a trefoil formation to optimize heat dissipation and minimize electromagnetic interference.

While every project is unique, we frequently encounter challenges that require our expertise and robust equipment:

  • High Pulling Tension: The weight and length of 132 kV cables can lead to high pulling forces. Our cable winches with integrated tension monitoring systems are designed to handle these loads safely.

  • Complex Routes: Navigating urban environments or difficult terrains with bends and obstacles requires the use of specialized rollers and precision planning.

  • Environmental Factors: Unforeseen soil conditions, high water tables, and adverse weather can impact timelines and require flexible, durable equipment.

  • Quality of Joints: A poorly executed cable joint is a major point of failure. Our recommended accessories and tools for cable jointing ensure a perfect, reliable connection every time.

Get the latest price? We'll respond as soon as possible(within 12 hours)
For a better browsing experience, we recommend that you use Chrome, Firefox, Safari and Edge browsers.